ball valve and Coil

    Electronic expansion valve controller is applicable for cooling systems such as room air conditioners, commercial air conditioners and freezers which is the core component for refrigerant flow control.

    Solenoid Valve
    Solenoid Valve Coil

    HIGH SHARING DESIGN

    • Adopting sharing PCB design (4 models), applicable for detections of three temperature sensors or one temperature and one pressure sensor
    • Applicable for split or packaged unit,either cooling or both cooling and heating with various voltage
    • Applicable for all Sanhua electronic expansion valves allowing trouble-free seclection and compatibility for customers
    • The controller is equipped with a whole set of advanced system control solutions for which parameters could be adjusted according to users’ requirements

    HIGH QUALITY DESIGN

      • Adopting overheat feedback control, PID core algorithm adjustment and control as well as functions such as abnormal protection control, defrosting control and sensor abnormal alarm
      • Using imported high quality elements for important components to ensure control accuracy of the controller
      • The bottom is painted with silica gel to improve dust-free, moistureproof and corrosion resistance performance
    Product Key Part Number Connections Kv PED

    category

    ODF [m3/h]
    Ø [in] Ø [mm]
    Without access fitting
    SBV(M)-A2YHSY-2-S SBV-13001 6 1,66 ART 3.3
    SBV(M)-A2YHSY-1-S SBV-13002 1/4 1,76 ART 3.3
    SBV(M)-A3YHSY-1-S SBV-13003 3/8 10 4,35 ART 3.3
    SBV(M)-A4YHSY-2-S SBV-13004 12 6,73 ART 3.3
    SBV(M)-A4YHSY-1-S SBV-13005 1/2 7,74 ART 3.3
    SBV(M)-A5YHSY-2-S SBV-13006 15 9,76 ART 3.3
    SBV(M)-A5YHSY-1-S SBV-13007 5/8 16 9,02 ART 3.3
    SBV(M)-A6YHSY-2-S SBV-13008 18 16,2 ART 3.3
    SBV(M)-A6YHSY-1-S SBV-13009 3/4 14,6 ART 3.3
    SBV(M)-A7YHSY-1-S SBV-13010 7/8 22 18,9 ART 3.3
    SBV(M)-A9YHSY-2-S SBV-13011 28 32,6 I
    SBV(M)-A9YHSY-1-S SBV-13012 1 1/8 34,9 I
    SBV(M)-A11YHSY-1-S SBV-13013 1 3/8 54,0 I
    SBV(M)-A13YHSY-1-S SBV-13014 1 5/8 42 77,6 I
    SBV(M)-A17YHSY-1-S SBV-13015 2 1/8 54 120,3 I
    SBV(M)-A17YHSY-2-S SBV-13016 64 111,7 I
    SBV(M)-A21YHSY-2-S SBV-13017 2 5/8 295,7 I
    SBV(M)-A25YHSY-2-S SBV-13018 3 1/8 80 361,9 I
    With access fitting
    SBV(M)-JA2YHSY-2-S SBV-13019 6 1,66 ART 3.3
    SBV(M)-JA2YHSY-1-S SBV-13020 1/4 1,76 ART 3.3
    SBV(M)-JA3YHSY-1-S SBV-13021 3/8 10 4,35 ART 3.3
    SBV(M)-JA4YHSY-2-S SBV-13022 12 6,73 ART 3.3
    SBV(M)-JA4YHSY-1-S SBV-13023 1/2 7,74 ART 3.3
    SBV(M)-JA5YHSY-2-S SBV-13024 15 9,76 ART 3.3
    SBV(M)-JA5YHSY-1-S SBV-13025 5/8 16 9,02 ART 3.3
    SBV(M)-JA6YHSY-2-S SBV-13026 18 16,2 ART 3.3
    SBV(M)-JA6YHSY-1-S SBV-13027 3/4 14,6 ART 3.3
    SBV(M)-JA7YHSY-1-S SBV-13028 7/8 22 18,9 ART 3.3
    SBV(M)-JA9YHSY-2-S SBV-13029 28 32,6 I
    SBV(M)-JA9YHSY-1-S SBV-13030 1 1/8 34,9 I
    SBV(M)-JA11YHSY-1-S SBV-13031 1 3/8 54,0 I
    SBV(M)-JA13YHSY-1-S SBV-13032 1 5/8 42 77,6 I
    • Applicable for all common HCFC and HFC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507
    • /max. ambient temperature: -30°C to +55°C
    • TS min./max.: -40°C / +120°C
    • PS: 4,83 MPa
    • Certifications: PED & UL

    Need Details in PDF

    You Can Download the Above Information as PDF